Normal Position (Vertical Direction)
Lever arm in vertical position, loud speaker and sign lamp off and electromagnetic break activate to hold lever crossing in vertical position. when a train passing the contact rail,
sign lamp, loud speaker and train direction indicator are set to on (active).
Working Position (Horizontal Direction)
Closing Gate bottom are pushed/turned from the panel door. lever crossing switched to off. A motor control the lever arm to move it down. the movement of lever arm can be stoped by
using the Stop botton, and simultaneusly will activated the electromagnetic break and swicthing off the electronic current to the DC motor.
Working Position (Vertical Direction)
After a train passing the crossing rail way, lever arm are being moved up by using the Open Gate button. in the same time sign lamp turn off and lever arm moved up a
view degree from vertical position, DC motor automatically switched off and electromagnetic break activated to hold the lever arm.
|